Support Centre

Find articles, help and advice.

 
Welcome, Guest Login

Support Center

BES - EDS Error: Failed to load selected View. unable to find required type

Last Updated: Jun 05, 2015 12:55PM UTC

Problem


In certain instances when a new dashboard is created from an existing file using the 'Save As' function it fails to load in the BSD with the following error:

Error: Failed to load selected View. unable to find required type, Please see .NET console for further details:

The .Net Console output shows:

15/05/19 14:41:55 ViewLoader.LoadAssembly Loading view into memory: [NEW_DASHBOARD_NAME]
15/05/19 14:41:55 ViewLoader.LoadAssembly : Failed to find expected type: [NEW_DASHBOARD_NAME]
15/05/19 14:41:55 ViewLoader.LoadAssembly : Assembly [NEW_DASHBOARD_NAME] has 1 types.
15/05/19 14:41:55 ViewLoader.LoadAssembly : [ORIGINAL_DASHBOARD_NAME]
 

Workaround


If you experience this problem you can take the following action to fix the immediate problem.
  1. Edit the EDS created file [NEW_DASHBOARD_NAME].xml using a standard text editor.
  2. Find and Change any occurrence of the [ORIGINAL_DASHBOARD_NAME] to the [NEW_DASHBOARD_NAME]
  3. Save the file
  4. Open the changed [NEW_DASHBOARD_NAME].xml in EDS and Upload.
 

Resolution


Not Currently Available.